IR FLAME DETECTORS

PTL-611 PORTABLE TEST LAMP FOR IR FLAME DETECTOR RIV-601P/F

All same as for RIV-601P/F model except:

  • Cast aluminium explosion-proof enclosure ADF-600AP model.
    External grey epoxy paint RAL7000 and internal anti-condensing orange paint RAL2004.
  • Type of protection II 2 GD Ex d IIC T6 Ex tb IIIC T85°C IP66 (85°C max case temperature, referred to 40°C ambient).
  • Conforms to ATEX Directive, BVI 14 ATEX 0007 certificate.
  • Dimensions: mm. 225x255x170h main body only (mounting holes 260×220 – overall dimensions 290×255).
  • Weight: kg. 10.5  case only – kg. 11.5 with detector inside.
  • Sensitivity reduced to 4% of the distance.
  • 1″ gas cable entry.

NOTE: In the model RIV-601P/FA the IR flame detector RIV-601P/F is to be mounted inside the explosion-proof case by the customer during the installation phase, through the front window, over the steel plate provided on the bottom.

  • DATASHEET